Trust Us

PVS – wire for rated voltage 380/660 V

Technical Specification

  • Maximum operating temperature of wire from -25ºС to + 40ºС;
  • Maximum relative humidity at +35°С temperature is 98%;
  • Maximum operating temperature of the lead core is not more than +70°C;
  • Electric resistance of the lead core at 20°С, converted to1 km length;
  • Electric resistance of wire insulation at 70°С, converted to1 km length after immersion in water for at least 2 hours – not less than 0,009 milliOhm;
  • AC Testing voltage 2 000 V works at frequency 50 Hz within 15 min with water storage at 20ºС;
  • Defined period of no-failure operating work - not less than 5000 hours;
  • Warranty working period of wires - two years since putting into operation;
  • Factory length to be agreed with customer.
  • Lead core wire is made from copper type MM corresponds to the 5th class of flexibility;
  • Insulation of the wire lead core is made from PVC incombustible elastron;
  • Insulated lead cores stranded into central core;
  • Stranded central core covered with jacket made from PVC incombustible elastron, so the jacket fills all gaps between lead cores making the whole wire round shaped. Jacket easily detaches without making harm for insulation.

Cable structure

Applications

PVS wires for rated voltage 380/660 V designed for connecting electric devices and tools for premises and facilities, laundry washers, refrigerators, rigging tools, grass mowers , extension cords etc.

 

Information for order

Type of the wire

Weight of 1 km of the wire, kg

Maximum outer diameter, mm

PVS 2х0,75

59,9

7,6

PVS 2х1

70,5

8,0

PVS 2х1,5

95,5

9,0

PVS 2х2,5

133,2

11,0

PVS 3х0,75

71,4

8,0

PVS 3х1

84,8

8,4

PVS 3х1,5

115,8

9,8

PVS 3х2,5

164,3

12,0

PVS 4х0,75

82,3

8,6

PVS 4х1

102,1

9,4

PVS 4х1,5

143,5

11,0

PVS 4х2,5

214,4

13,0

PVS 5х0,75

106,3

9,6

PVS 5х1

127,1

10,0

PVS 5х1,5

183,9

12,0

PVS 5х2,5

274,2

14,0

Support request

Support request