Trust Us

rek-1HH-M Termination Kits

for 3, 4 and 5 - core cables with insulation from vulcanized (cross linked) polyethylene for 1 kV voltage

Technical performance

rek-1HH-M termination is used for 3, 4 and 5-core cables with XLPE insulation, for the voltage up to 1 kV.

The kit includes:

  1. Universal tear-off head bolt lugs from GPH Company;
  2. Special tapes;
  3. Kit for armor connection;
  4. Heat shrinkable tubes;
  5. Installation manual.

Structure of the termination kit

Termination of the cores is made by tear-off head bolt lugs. The construction of the termination box consists of heat shrinkable parts. Cable root is seals with heat shrinkable breakouts which have thermo melting glue on the inner surface. The cores of the cable are protected with 800 mm shrink insulation tube. The space between the lug and insulated cores sealed with shrink tube with adhesive layer.

Installation

  • Preparation of the cable is made in accordance with installation manual for the termination box.

Application

rek-10HH-3-M terminations is designed for indoor and outdoor termination of 3, 4 and 5-core cables with XLPE insulation, PVC sheath, armored with steel tape or wire* on voltage up to 6 kV and 10 kV, operated under temperature from -500C to +500C, with relative humidity up to 80%, in cable structures.

Features

The rek-1HH-M type terminations correspond to ST TOO 41021646-14-2007 and meet the requirements of GOST 13781.0-86 (State Standard).

Kit

The kit can be supplied without lugs or with pressure lugs for copper or aluminum cores by the request of the customer.
The standard length of core cut is 800 mm. The length of the core cut can be from 450 to 1200 mm after by the customer request.
Example of the order for termination with core termination length 1200 mm: rek-1HH-4-35/50-1200-M.
Example of the order for termination with core termination length 450 mm: rek-1HH-4-35/50-450-М.

Cable type

APvVG, PvVG, APvBbShv, PvBbShv, APvVng (A)-LS, PvVng (A)-LS, APvBbShng (A)-LS, PvBbShng (A)-LS, APvBbShp, PvBbShp, APvBbShpg etc.

Order arrange table

Nominal voltage, kV

Cross section mm2

Number of cores in the cable

Order name

Core termination length mm (L)

Unarmored cables

Tape armor cables

up to 1

16/25

3

rek-1HH-3-16/25-М

rek-1HH-3-16/25-АМ

800

up to 1

35/50

3

rek-1HH-3-35/50-М

rek-1HH-3-35/50-АМ

800

up to 1

70/120

3

rek-1HH-3-70/120-М

rek-1HH-3-70/120-АМ

800

up to 1

150/240

3

rek-1HH-3-150/240-М

rek-1HH-3-150/240-АМ

800

up to 1

16/25

4

rek-1HH-4-16/25-М

rek-1HH-4-16/25-АМ

800

up to 1

35/50

4

rek-1HH-4-35/50-М

rek-1HH-4-35/50-АМ

800

up to 1

70/120

4

rek-1HH-4-70/120-М

rek-1HH-4-70/120-АМ

800

up to 1

150/240

4

rek-1HH-4-150/240-М

rek-1HH-4-150/240-АМ

800

up to 1

16/25

5

rek-1HH-5-16/25-М

rek-1HH-5-16/25-АМ

800

up to 1

35/50

5

rek-1HH-5-35/50-М

rek-1HH-5-35/50-АМ

800

up to 1

70/120

5

rek-1HH-5-70/120-М

rek-1HH-5-70/120-АМ

800


* The of termination kit with wire armor cable is ordered separately.