Trust Us

PKSV / ПКСВ - Cross station wires with PVC elastron insulation

Technical Specifications

  • Cross station wires with PVC elastron insulation in accordance with ST TOO 41021646-07-2007 (Company Standard);
  • ultimate operating temperature from -10°С to +50°С and degree of air humidity up to 98% at temperature +35°С;
  • electrical resistance for a length of 1km with diameter 0.4mm – not more than 150 Ohm; 0.5mm – not more than 96 Ohm;
  • electrical resistance of wire insulation for a length of 1km at temperature +20°С - not less than 1000MOm;
  • testing AC voltage, frequency 50Hz 1200V.

Cable Structure

  • copper electrical conductors with diameter of 0.4mm or 0.5mm in accordance with TU 3518 PK 4043838373-TOO-17-2003;
  • PVC compound in accordance with GOST 5960-72 (State Standard);
  • color of insulation in accordance with ST TOO 41021646-07-2007 (Company Standard);
  • insulating cores are twisted.

Application

Wires are meant for non-stationary including in cross telephone stations’ buildings at DC up to 120V.

Order arrange table

Wire Type

External wire diameter, mm (not more than)

Nominal weight of 1km wire, kg

Factory length, m (not less than)

PKSV 2×0,4

2,0

4,6

100

PKSV 3×0,4

2,2

6,9

100

PKSV 4×0,4

2,6

9,2

100

PKSV 2×0,5

2,2

6,3

100

PKSV 3×0,5

2,4

8,5

100

PKSV 4×0,5

2,7

11,3

100

Support request

Support request