KRVPM - distributing few - pairs cables

Technical Specifications

• Maximum operating temperature in fixed assembly conditions ranging from -15°С up to +65°С;

• Relative air humidity at 35 оC, not greater 98%;

• Nominal maximum DC - resistance conductor at 20°С (Ohm/km) for the following cross-sections: 0,4 mm – not greater 150 Оhm; 0,5 mm – not greater 96 Ohm; 0,8 mm – not greater 36,6 Оhm;

• Nominal maximum DC – resistance insulation at 20°С (Ohm/km), not less 150 МOhm;

• Ohm asymmetry of cores in working pair – not greater 3,0 %;

• Pair electric capacitance for 0,1 кm at 0,8 KHz – not greater 5,6 pF;

• Attenuation ratio for pair twisted cables at 100 m wave length, not greater

1 MHz – not less 60 dB;

4 MHz – not less 53 dB;

10 MHz – not less 47 dB;

16 MHz – not less 44 dB;

20 MHz – not less 42 dB;

62,5 MHz – not less 35 dB;

100 MHz – not less 32 dB;

• Testing voltage between DC cores – 1000 V;

• Minimum bending radius - not less 10 x overall diameter

Cable’s structure

1- Conductive core made of copper

2- Conductor insulation

3-Cable’s sheath

  • Conducting core is made of MM class copper wire;
  • Cores are insulated with polyethylene;
  • Two insulated cores are twisted into symmetrical pair, twisted pairs and single core are twisted then into a core;
  • Cable core may be produced of non-twisted pairs or single cores;
  • Cable jacket is made of flame retardant PVC Elastron;
  • Jacket color: white, gray, black.*

* If customized, jacket color may be of any color

Application

Twisted pair cables are design for permanent laying inside buildings and constructions, for usage in telecommunication networks and for devices connection in computer networks. Cables are used in frequency diapason up to 16 МHz (class 3), at working AC voltage not greater 145 V. cables with conducting core of 0,5 mm diameter are used in frequency diapason up to 100 МHz (class 5), at working AC voltage not greater 145 V.

Cables of unpaired twisting are design for permanent laying inside the building and constructions, for usage in fire- alarm and alarming devices, connection of control equipment and automatics.

Cable type

Outer cable diameter (mm)

Approximate cable weight (kg/km/)

Factory length, m

KRVPM 1х2х0,4

3,0

9,2

100

KRVPM 1х2х0,5

3,2

11,1

KRVPM 1х2х0,8

3,5

19,1

KRVPM 2х2х0,4

3,8

14,1

KRVPM 2х2х0,5

4,5

18,9

KRVPM 2х2х0,8

6,0

36,5

KRVPM 3х2х0,4

5,0

19,8

KRVPM 3х2х0,5

5,5

26,1

KRVPM 4х2х0,4

5,3

21,4

KRVPM 4х2х0,5

6,0

27,8

KRVPM 5х2х0,4

5,5

29,4

KRVPM 5х2х0,5

5,7

36,7

KRVPM 25х2х0,4

13,8

120,2

KRVPM 25х2х0,5

15,0

164,7

KRVPM 1х4х0,4

3,4

13,4

KRVPM 1х4х0,5

3,6

16,7

KRVPM 1х5х0,4

3,7

15,9

KRVPM 1х5х0,5

3,9

20,7

KRVPM 1х6х0,4

3,9

18,7

KRVPM 1х6х0,5

4,2

22,9