TPPShv / ТППШв – Communication telephone cables

Technical Specifications

  • Telephone cables are made in accordance with ST TOO 41021646-06-2007;
  • operating temperature from -40°С to +50°С; at construction conditions: from -10°С to +50°С;
  • insulation resistance for a length of 1km at temperature of +20°С – not less than 6500 MOhm;
  • testing voltage during 1 minute: between cords of a working pair -1500V; between cords and shield – 750V (for cables 200V); between cores and shield – 3000V (for cables up to 315V);
  • working capacity - 45±5 nF/km;
  • asymmetry of capacity to a shield – not more than 250 nF/km;
  • capacity coupler between cores of pairs, (k) – not more than 100 nF/km;
  • NEXT, frequency 1024 kHz - not less than 51 dB;
  • wave resistance, frequency 1024 kHz - 100±15 Ohm;
  • cable attenuation on a frequency of 1.0 kHz (not more), for core with diameter of: 0.4mm – 2.0 dB; 0.5mm – 1.6 dB; 0.64mm – 1.2 dB.

Cable Structure

  • copper electrical conductors in accordance with TU 3518 PK 4043838373-TOO-17-2003;
  • PE insulation in accordance with TU 6-11-00203335-97-95;
  • two cores twisted in a pair, the pairs twisted in sub-unit, then sub-units twisted in a strand;
  • marking and color are in accordance with ST TOO 41021646-06-2007 (Company Standard);
  • wrapping (PE or PVC tape);
  • a shield is made of alumina-PE tape;
  • four tinned copper wires are under a shield;
  • PE sheath is made in accordance with GOST 16336-77;
  • external jacket is made of light-stabilized self-extinguishing PVC compound in accordance with GOST 5960-72.

Application

TPPShv/ТППШв cable is used in local telephone network and in telecontrol with frequency, pulse-duration and pulse-position modulation of signals up to 1048 kHz and voltage up to 225V for a frequency of 50 Hz or DC voltage of 315V. Cables are used for outdoor and indoor laying, including explosive and combustible environment and premises with chemically active substance within maximum permissible concentration, building walls, in a cable structure and cable-conduit line. Also it can be used under extra air-pressure.

Application of closures for the cable:

Connecting closures – MIKS;
Compression closures – SSK, VSSK;
Compression closures – SSK (arm), VSSK (arm);
Connecting and splicing closures MS, MR;
Gas dam – GNS, GNS (for mining works);
Gas dam – GNSK.

Order arrange table

Type

Number of pairs

External cable diameter with cores diameter of, not more than, mm

Weight of a cable with cores diameter of, not more than, kg/km

Factory length, not less than, m

0.4

0.5

0.64

0.4

0.5

0.64

TPPShv

5

12,5

13,9

15,1

106

119

147

500

10

14.0

14,9

18,1

142

162

204

400

20

16.5

18.7

22.5

201

254

340

400

30

18.8

20.8

25.1

271

324

446

300

50

21.6

25.2

31.0

374

475

697

300

100

27.1

32.7

37.9

617

807

1220

300