Trust Us

RK / РК - coaxial cable with solid insulation of regular heat resistance

Application

Coaxial cables with solid insulation of typical heat resistance are produced according to the GOST 11326.0-78. Coaxial radio-frequency cables represent an independent class of radio-frequency lines of information transfer and used for transmission of radio and video signals in a range from meter to centimeter wave lengths. Radio-frequency cables are applied in antenna and feeding devices, in radio - and television receivers, for inside - and interblock connections in radio-electronic equipment. Coaxial type cables which in comparison with two-core cables possess higher noise immunity and very small losses in a wide range of frequencies are the mostly widesread. The working range of frequencies of coaxial radio-frequency cables is from 10*(7) to 10*(10) Hz.

Technical parameters

Title

Outer diameter, mm

Cable type

RK 50-2-11

RK 50-4-11

RK 75-2-11

RK 75-4-11

RK 75-4-12

RK 75-7-12

RK 75-9-12

RK 75-9-13

RK 100-7-11

RK 100-7-13

Temperature range

°С

-60…+85

-60…+85

-60…+85

-60…+85

-60…+85

-60…+85

-60…+85

-60…+85

-60…+85

-60…+85

Min. atmospheric pressure

кPa

0,67

0,67

0,67

0,67

0,67

0,67

0,67

0,67

0,67

0,67

Max. atmospheric pressure

кPa

300

300

300

300

300

300

300

300

300

300

Relative air humidity at 35 ºС

%

98

98

98

98

98

98

98

98

98

98

Wave resistance

Ohm

50±2

50±2

75±3

75±2,5

75±2,5

75±2,5

75±2,5

75±2,5

100±5

100±5

Attenuation coefficient (at frequency)

dB/m (GHz)

0,3(0,2)
1,6(3)

1,15(3)
3(10)

1,8(3)

0,18(0,2)
0,9(3)

0,18(0,2)
0,9(3)

0,14(0,2)
0,85(3)

0,12(0,2)
0,75(3)

0,12(0,2)
0,75(3)

0,13(0,2)
0,85(3)

0,13(0,2)
0,85(3)

Rated electrical volume for 1 m of the cable

pF

100

100

67

67

67

67

67

67

51

51

Velocity factor

-

1,52

1,52

1,52

1,52

1,52

1,52

1,52

1,52

1,52

1,52

Coupling impedance of 1 m of cable (not more)

mOhm

320

10

320

200

200

200

200

200

200

200

Internal voltage, (not less)

kV

1,5

3,0

1,3

2,5

2,0

3,0

4,5

4,5

3,0

3,0

Minimum bending radius, not less

mm

40

100

70

70

70

100

120

120

100

100

Factory length, not less

m

50

50

25

100

50

50

100

100

50

50

Cable structure

Title

Cable type

RK 50-2-11

RK 50-4-11

RK 75-2-11

RK 75-4-11

RK 75-4-12

RK 75-7-12

RK 75-9-12

RK 75-9-13

RK 100-7-11

RK 100-7-13

Inner conductor type

Copper

Copper

Copper

Copper

Copper

Copper

Copper

Copper

Copper

Copper

Inner conductor construction

1х0,67

1х1,37

1х1,37

1х0,72

7х0,26

7х0,4

1х1,4

1х1,4

1х0,6

1х0,6

Insulation material

PE

PE

PE

PE

PE

PE

PE

PE

PE

PE

Outer conductor type

Copper

Copper

Copper

Copper

Copper

Copper

Copper

Copper

Copper

Copper

Outer conductor construction

Braiding

2-layer  braiding

Braiding

Braiding

Braiding

Braiding

Braiding

Braiding

Braiding

Braiding

Jacketing material

PE

PE

PE

PE

PE

PE

PVC

PE

PE

PVC

Outer diameter, mm

3,7±0,2

7,8±0,25

3,0±0,2/-0,1

7,0±0,25

7,0±0,25

10,0±0,3

12,0±0,4

12,0±0,4

9,7±0,3

9,7±0,3

Support request